Choosing The Right Size Polythene Cover For A Polytunnel Is Essential. The Sheet Must Pass Over The Curved Hoops, Extend Along The Tunnel And Provide Enough Extra Material For Secure Fixing.
This independent guide explains how to measure accurately and calculate the sheet dimensions without relying on the advertised ground width alone. Learn How to Measure A Polytunnel, aka tunnel or Hoop House, and buy the right size polytunnel sheet.What size polythene cover do I need?
Covers, also known as sheets, come in standard sizes, so you need to measure your polytunnel carefully and buy a size that will cover it. Below, I describe how I measure tunnels. It isn’t difficult if you follow this guide. Once you have the measurements, you can use the calculator to determine the size of sheet you need. But don’t forget that you then need to buy a sheet that’s at least that size, and the next available standard size may be considerably bigger. Standard-sized tunnels use standard-sized sheets, and that makes things easier. Homemade tunnels tend to be built to non-standard sizes, so bear this in mind if you’re going to build your own polytunnel frame. My polytunnels were all standard commercial sizes, either 120 Ă— 14 ft or 120 Ă— 18 ft. Those extra four feet of width also meant much more height, so we could drive a tractor through the wider ones! The smaller ones would only accommodate a wheeled rotavator and trailer. There’s a huge difference when you’re trying to be efficient!What We Need To Cover
You need the distance measured over the curved hoops, the length of the tunnel and an appropriate fixing allowance on both sides and at both ends. Ground width alone is not enough: two tunnels of identical width may have very different hoop profiles.How to Measure A Polytunnel
1. Measure the curved hoop
Using a flexible tape or non-stretch string, measure from the fixing point on one side, over the outside of the hoop and down to the corresponding fixing point on the other side. Do not simply measure across the ground.
2. Measure the tunnel length
Measure the length of the framework from one end to the other. Allow additional material at both ends according to the way the cover is secured.
3. Measure the height
Measure from ground level to the top of the framework. Height helps when assessing the material required at the tunnel ends, especially where the sheet folds around the end frames.
4. Identify the fixing method
Trenching and base-rail fixing require different allowances. Â Calculate the full width of polythene needed for the fixing method rather than assuming a universal extra allowance.Trench fixing: allow for the full trench width
Where the cover is buried, the extra polythene must run down to the bottom of the trench, across the bottom and up the far side on each side of the tunnel. Include that entire width in your allowance, as well as any material needed for tensioning and anchoring. There is a section in the calculator for this. Just add in the extra you need for one side and it will be used to calculate the size needed.Polytunnel sheet size calculator
Use the following formula to estimate the sheet size. Enter your own fixing allowances, based on the actual trench or rail arrangement. Sheet width = curved hoop measurement + (2 Ă— allowance per side). Sheet length = tunnel length + (2 Ă— height to top of arch) + (2 Ă— additional fixing allowance per end). For example, a 5.5m hoop measurement plus 0.5m on each side gives a 6.5m sheet width. For a 6m tunnel with a 2m arch height and 0.5m additional fixing allowance at each end, the sheet length is 6 + (2 Ă— 2) + (2 Ă— 0.5) = 11m. These allowances are examples only, not universal recommendations.Calculate your polythene sheet size
Enter measurements in metres. The side allowance is added twice; the full arch height and any additional end-fixing allowance are added at each end. This assumes the main sheet folds down over both ends.Example allowances are prefilled for illustration only. For trenches, include the full route down, across the bottom and up the opposite wall. Check your actual fixing requirements.
Common polytunnel widths
| Nominal ground width | Metric equivalent |
|---|---|
| 6ft | 1.83m |
| 8ft | 2.44m |
| 10ft | 3.05m |
| 12ft | 3.66m |
| 14ft | 4.27m |
| 16ft | 4.88m |
| 18ft | 5.49m |
| 20ft | 6.10m |
Common measuring mistakes when you measure a polytunnel
Measuring straight across the tunnel instead of over the hoop.
- Forgetting the material needed for trench bottoms and the opposite trench walls.
- Using the same allowance for trenching and base rails.
- Mixing feet and metres.
- Cutting the sheet before positioning and tensioning it.